亿安腾
亿安腾
Application Product Center About us News Contact
Chlor alkali chemical industry
Electrolytic copper foil
Electronic plating
Hydrometallurgy
Steel plate electroplating
Metal plating
more +
Ruthenium Series MMO Anode
Iridium Series MMO Anode
Platinum Plated Titanium Anode
Lead Dioxide Coated Titanium Anode
Platinum Plated Niobium Anode
BDD Anode
Electrolyzer design and production
Organic synthesis cell
Profile
Factory
Company News
Industry information
Sales:(+86)527-8768 6007
            (+86)138 1570 1819
Fax:(+86)527-8768 6000
E-mail:szphm@vip.126.com
Mr Pan:(+86)136 0621 8252
Mr Chen: (+86)13815701819
Add:No.1, Zhangqi Road, National Economic Development Zone, Shuyang County, Jiangsu Province

 

Causes of electroplating anode slime and application of electroplating auxiliary anode and electroplating insoluble anode
MMO insoluble titanium anode for electroplating
MMOinsolubletitaniumanodeforelectroplatingFirst,iridium-tantalum(Ir-Ta)coatedelectrodeOxygen-resistantelectrodeismainlyusedforoxygenevolutionreaction,especiallysuitableforacidelectrolyte,suchasacertainconcentrationofsulfuricacidelectrolyte,theoxygenisverylow,canbeusedforoxygenreleaseelectrolysis,alsoresistanttothecorrosionofchlorine,canbeusedforoxygenreleaseandchlorinereleaseelectrolysisSuchasseawaterelectrolysis,etc.Itisanelectrodematerialwithgoodoxygenreleasereactioninacidicmedium.Inthisenvironment,theavailableelectrodematerialsarelimited.Thecoatedelectrodehasbeenusedinorganicelectrolysis,suchascysteine,glyoxylicacid,succinicacid,etc.,whichcanbeusedforCr3+﹢→Cr6+electrolysisofindirectoxidationoforganicelectrolysis,andsewagetreatmentisusedtooxidizeorganicandtoxicsubstancesinwater.SuchasCN-transformation.Itcanalsobeusedintheelectroplatingindustryasauxiliaryelectrodes,suchasauxiliaryanodesforCrplating,auxiliaryanodesforelectrolyticcopper,andthelike. two,Ruthenium-titanium-iridium(Ru-Ti-Ir)ternarycoatingelectrodeThecoatedelectrodeisusedforelectrolytescontaininghighhydroxideradicals,isresistanttooxygencorrosion,andissuitableforionmembraneelectrolysis.Coatingindex:1.Thedischargepotentialis1.18volts(S.C.E)atacurrentdensityof4000A/m2.2.Strengthenedlife(coatingweightlossmethod)1.02mv/4hours4cm2,theservicelifeisguaranteedformorethan5years,andithasbeenappliedtoindustriallargeelectrictanks. Three,ruthenium-titanium-tin(Ru-Ti-Sn)ternarycoatingelectrode ThetechnologyhasbeensuccessfullydevelopedandhaswontheScienceandTechnologyProgressAwardoftheMinistryofChemicalIndustry.Coatingcharacteristics: 1.Thechlorineevolutionpotentialislowandtheoverpotentialissmall.At2000A/m2currentdensity,thechlorinegasdischargepotentialisnotgreaterthan1.12V,andtheoverpotentialislessthan20mv. 2.Thepolarizationrateislessthan30mv/10unitcurrentdensity. 3.Longerlife-span:0.5NH2SO4,1A/cm2currentdensity,lifespanisgreaterthan1500minutes. Theabovethreeindicatorsarebetterthantheindustryspecifiedindicators(industrialindicatorsare:potential1.13volts,polarizationrate40mv/10unitcurrentdensity,enhancedlifeisgreaterthan1000minutes). Fourth,titaniumplatinum(Ti/Pt)coatedelectrodeBasemetal:Gr1,Gr2,TA1,TA2 Workingcurrentrange:<2000A/m2 Temperaturerange:<80℃ Coatedmetal:Pt(99.99%) Shape:plate,tube,etc.Technicalcharacteristics:Itisaninsolubleanode.Theplatinumplatinglayerisfirmlycombinedwiththetitanium-basedsubstrateandtheuseperformanceisstable.Itcanreplacepuregoldandpureplatinumanodesforgoldandotherpreciousmetalplatingtanks.Application:Acidandalkalineplatingsolution Five,titanium-basedmaterialsprocessingrequirements:Surfaceroughness:Thereisnorelevantstandardforthisitem,therougherthebetter.Platenetanodesurfaceflatness:thickness1.5ormore≤±0.5mm/M,thickness1.0orless≥±1.0mm/M,Tubeanodestraightness:wallthickness1.5mmabove±0.5mm/M,wallthickness1.5mmbelow±1.0mm/MBlankingtoleranceofplateprocessedparts:theminimumcanbecontrolledwithin±0.1mm,andthegeneraldeliverytoleranceiswithin±0.5mm Six,theuseoftitaniumanodeproducts: DSAisnotatrueinsolubleanode,it'sjustthattheconsumptionrateislow.Dependingontheapplicationindustryandthespecificuseenvironment,ourcompanycanguaranteeaguaranteedserviceliferangingfrom0.5-50years.1.Withinthenormalworkingcurrentdensityof2000A/m²,theexcessivecurrentwillcausethereactiontobetoointenseandshortentheanodelife;2.Theelectrolytemustnotcontaincyanideandfluorideions.Theseimpuritiescanseverelycorrodethetitaniummatrix;3.Theanodeandanodepoledistancecanbesetaccordingtothespecificsituation,generally5-25mm.Generallyspeaking,thepoledistanceincreasesthepowerconsumption,andatthesametime,itshouldnotbetoosmall,otherwisethecathodescalegeneratedonthecathodesurfaceislikelytocausetheshortcircuitoftheplate;4.Itisstrictlyforbiddentouselead.Oncethepreciousmetaloxidecoatingisusedasacathode,areductionreactionoccursonthesurface,anditiseasytobeconvertedintoametalelement,whichcannoteffectivelycombinewiththetitaniumbase,causingthecoatingtofalloff.Considerperiodicallyaddingacidtocleanthesurfaceoftheplate.,5.Thetemperatureoftheelectrolyteshouldnotbetoohigh,theidealtemperatureis25-40°C.6.Rinsethesurfaceoftheplatewithcleanwaterduringshutdown.Itshouldnotbeimmersedinthesolutionforalongtimeafterpoweroff.Ifpossible,itisbesttomaintainasmallcurrentof2-5Atomeetthecycletoprotecttheplate.7,installationandhandlingneedtobecareful,thecoatingsurfacemustnotbescratched,otherwiselocalcorrosionwillsoon.
What does TOD, TOC, BOD, COD mean in industrial wastewater treatment? What is the connection between them?
WhatdoesTOD,TOC,BOD,CODmeaninindustrialwastewatertreatment?Whatistheconnectionbetweenthem?Therearetwotypesofcomprehensiveindicatorsforthecontentoforganicmatterinwater.Oneisanindicatorthatisequivalenttotheamountoforganicmatterinwater(O2),suchasBOD,chemicaloxygendemand(COD),andtotaloxygendemand(TOD).;Theotherisanindicatorexpressedincarbon(c),suchastotalorganiccarbonTOC.Forthesamekindofsewage,thevalues​​oftheseindicatorsaregenerallydifferent,andtheorderofthevalues​​isTOD>COD>BOD5>TOC. 1.TOD Totaloxygendemand(TOD)referstotheamountofoxygenrequiredforreducingsubstancesinwatertobecomestableoxidesaftercombustionathightemperatures.Theresultsareexpressedinmg/L.TheTODvaluecanreflecttheoxygenrequiredtoconsumealmostallorganicmatterinwater(includingcarbonC,hydrogenH,oxygenO,nitrogenN,phosphorusP,sulfurSandothercomponents)aftercombustionintoCO2,H2O,NOx,SO2,etc.theamount. 2.TOC TotalorganiccarbonTOCisacomprehensiveindicatorthatindirectlyexpressesthecontentoforganicmatterinwater.Thedataitshowsisthetotalcarboncontentoforganicmatterinsewage.Theunitisexpressedinmg/Lofcarbon(c).TheTOCofgeneralurbansewagecanreach200mg/L,theTOCrangeofindustrialsewageiswide,thehighestcanreachtensofthousandsofmg/L,andtheTOCofsewageaftersecondarybiologicaltreatment-generally<50mg/L. 3.BODBOD Biochemicaloxygendemandiscalledbiochemicaloxygendemand,whichisabbreviatedasBOD.Itmeanstheamountofdissolvedoxygenconsumedduringthebiochemicaloxidationprocessofaerobicmicroorganismstodecomposeorganicmatterinwateratatemperatureof20°Candaerobicconditions.Theamountofoxygenrequiredtostabilizebiodegradableorganicsinwater,theunitismg/L.BODincludesnotonlytheamountofoxygenconsumedbythegrowthandreproductionofaerobicmicroorganismsinthewater,butalsotheamountofoxygenconsumedbyreducinginorganicsubstancessuchassulfidesandferrousiron,buttheproportionofthispartisusuallysmall. Undernaturalconditionsat20°C,thetimerequiredfortheorganicmattertooxidizetothenitrationstage,thatis,toachievecompletedecompositionstability,ismorethan100d.However,BOD20,whichiscommonlyusedat20°Cfor20d,approximatelyrepresentsthecompleteBOD.Itisstillconsideredthatthetimeof20distoolonginproductionandapplication.Generally,theBOD5ofBOD5of5dat20℃isusedasanindextomeasurethecontentoforganicmatterinsewage. 4.COD Chemicaloxygendemand(COD)referstotheamountofoxygenconvertedintooxygenbytheconsumptionoforganicsubstancesinwaterandstrongoxidantsundercertainconditions,inmg/Lofoxygen.Whenpotassiumdichromateisusedastheoxidant,almostalloftheorganicmatterinthewater(90%to95%)canbeoxidized.Atthistime,theamountofoxygenconsumedbytheoxidantconvertedintooxygenisgenerallycalledchemicaloxygendemand,whichisoftenabbreviatedasCODcr.TheCODcrvalueofwastewaterincludesnotonlytheoxygenconsumptionofalmostallorganicsubstancesinthewater,butalsotheoxygenconsumptionofreducinginorganicsubstancessuchasnitrites,ferroussalts,andsulfidesinthewater. 5.TherelationshipbetweenBOD5andCOD BOD5isnotonlyanimportantwaterqualityindicator,butalsoanextremelyimportantcontrolparameterinthebiologicaltreatmentprocessofsewage.However,duetothelongmeasurementtime(5d),itcannotreflectandguidetheoperationofthesewagetreatmentdeviceintime,andcanonlybeusedforprocesseffectevaluationandlong-termWangYiregulation.Foraspecificsewagetreatmentplant,thecorrelationbetweenBOD5andCODcanbeestablished,andaroughestimateoftheCOD5valueofCODisusedtoguidetheadjustmentofthetreatmentprocess.Sometimes,becausesomeproductionwastewaterdoesnothavetheconditionsforthegrowthandreproductionofmicroorganisms(suchasthepresenceoftoxicorganicsubstances),itsBOD5valuecannotbeaccuratelydetermined. Thechemicaloxygendemand(COD)valueofsewagecanbeusedtoaccuratelydeterminethecontentoforganicmatterinwater,butCODcannotdistinguishbetweenbiodegradableorganicmatterandnon-biodegradableorganicmatter.PeopleareusedtomeasuringtheBOD5/CODofsewagetodetermineitsbiodegradability.ItisgenerallybelievedthatsewagecanbetreatedbybiodegradationifitsBOD5/CODisgreaterthan0.3.IftheBOD5/CODofsewageislowerthan0.2.Onlyothermethodscanbeconsideredforprocessing. TheCODvalueofthechemicaloxygendemandisgenerallyhigherthantheBOD5valueofthebiochemicaloxygendemand,andthedifferencebetweenthemcanroughlyreflecttheorganicmattercontentinthesewagethatcannotbedegradedbymicroorganisms.Forsewagewithrelativelyfixedpollutantcomponents,thereisgenerallyacertainproportionalrelationshipbetweenCODandBOD5,whichcanbecalculatedfromeachother.Inaddition,themeasurementofCODtakeslesstime,andthenationalstandardmethodfor2hoursofrefluxisusedtoperformthetest.Ittakesonly3to4hoursfromthesamplingtotheresult,andtheBOD5valuetakes5days.CODisoftenusedasacontrolindicator. Inordertoguidetheproductionandoperationassoonaspossible,somesewagetreatmentplantshavealsoestablishedenterprisestandardsformeasuringCODfor5minutesatreflux.Althoughthemeasuredresultsaresomewhatdifferentfromthenationalstandardmethod,theerrorsaresystematicerrorsandtheresultsofcontinuousmonitoringcanaccuratelyreflectthewaterquality.Theactualchangetrendofthemeasurementtimecanbereducedtolessthan1h,whichprovidesatimeguaranteeforti
The principle of forced current cathodic protection and the relationship between auxiliary anode corrosion rate and current density
Theprincipleofforcedcurrentcathodicprotectionandtherelationshipbetweenauxiliaryanodecorrosionrateandcurrentdensity First,theprincipleofforcedcurrentcathodicprotection Thetraditionalmetalanti-corrosionmethodismainlyisolationandanti-corrosion,thatis,toisolatemetalfromcorrosivemedium.Specificmeasuresincludecoatings,coatings,andplating.Anothermethodistochooseacorrosion-resistantmetal,suchasstainlesssteel,copper,titanium,etc.;orothermaterialssuchasplastic,fiberglass,etc.ifpossible. However,becausethecorrosiveenvironmentisalmostubiquitous,theformsofcorrosionarealsovarious.Asingleanti-corrosionmeasureoftencannoteffectivelycontrolmetalcorrosion,especiallyelectrochemicalcorrosion.Onceametalstructureisformedwithacorrodedbattery,theanoderegionhasamuchsmallerareathanthecathoderegion,andthecorrosionrateisextremelyfast.Atthistime,themetalsurfaceisnotuniformcorrosion,butpittingcorrosion.Almostallundergroundoilandgaspipelines,storagetanks,andvariouscontainersandequipmentcontainingelectrolytesleakduetopittingcorrosion. Cathodicprotectionistheuseoftheprincipleofcorrodingthebattery.Themetalstructuretobeprotectedisusedasthecathode,andtheanodeiscontinuouslysuppliedwithelectronsthroughtheanode.Thestructureisfirstpolarizedandtheelectronsareenrichedonthesurfaceofthestructure,makingitdifficulttogenerateions.Greatlyslowdowntherateofcorrosionofthestructure.Cathodicprotectionisroughlydividedintotwotypes:sacrificialanodemethodandappliedcurrentmethod(forcedcurrent).Theanodesusedinthesacrificialanodemethodaremagnesium,aluminum,andzincactivemetalalloyanodes;theanodesusedintheforcedcurrentmethodareMMO(mixedmetaloxide)titanium-basedcoatinganodesasauxiliaryanodes.Theforcedcurrentmethod(externalcurrentmethod)istoapplyacathodiccurrenttotheprotectedstructureandananodecurrenttotheauxiliaryanodetoformacorrodedbattery.Themetalstructureisprotectedonthesameprinciple.Itiseconomicalandhasalonganodeservicelifewhenimplementinglarge-scalefieldcathodicprotection.  Externalcurrentcathodicprotectionauxiliaryanode Second,therelationshipbetweenauxiliaryanodecorrosionrateandcurrentdensity Relationshipbetweenanodecurrentdensityandcoatingconsumption Relationshipbetweenanodecurrentdensityandlife Asshowninthefigureabove,astheanodecurrentdensityincreases,theconsumptionrateofthecoatingalsoincreases,andtheservicelifealsodecreases.
Page up
1
2
3